¹·Íò¹ÙÍø

¹·Íò¹ÙÍø

ÌìÏÂ×Éѯµç»°£º
13955040807

µçÀÂÐÂÎÅ

DCK DCKP DCKPJ»ú³µµçÀÂÉú²ú³§¼Ò

DCK DCKP DCKPJ»ú³µµçÀÂÉú²ú³§¼Ò

Ò»¡¢DCK DCKPÖ´Ðбê×¼standards£º
Q£¯12 YJ 4170-2004
¶þ¡¢DCK DCKPÄÍѹƷ¼¶Voltage£º450/750V
Èý¡¢²úÆ·½á¹¹Structure£º
µ¼µçÏßо+¾øÔµ²ã+ÄڳƲã+(ÆÁÕϲã)+Í⻤²ã
Conductor + insulation + inner jacket+(shield)+outer sheath
ËÄ¡¢DCK DCKPÉú²ú¹æÄ£Product specification£º
оÊýΪ2¡«61о£®½ØÃæÎª0.5¡«2.5mm2¡£¡£¡£¡£¡£
The number of cores is 2-61£®cross--section£º0£®5-2.5 mm2¡£¡£¡£¡£¡£
Îå¡¢DCK DCKPÊÊÓùæÄ£Applications£º
±¾²úÆ·ÊÊÓÃÓÚ½»Á÷¶î¶¨µçѹ450£¯750V¼°ÒÔÏÂÌúµÀ¼°¿óɽµÈÖÖÖÖÀàÐÍ»ú³µ³µÁ¾¼°´¬²°¡¢Ê¯ÓÍÆ½Ì¨¡¢ºËÄܹ©µçϵͳÓᣡ£¡£¡£¡£ÌØÊâÊÊÓÃÓÚÒªÇóÄÍÎÂÆ·¼¶¸ß¡¢ÓпóÎïÓÍ»òȼÁÏÓÍÎÛȾµÄ³¡ºÏ¡£¡£¡£¡£¡£
It is suitable for use in various locomotive vehicles OR ships¡¢oil-platform and some supply circuit Of nuclear energy in railroad and mine£®intended for power at voltages up to and including450£¯750V£®Especially suitable for use at environment such as required high temperature£®Mineral-oil or fuel-oil polluted occasions
Áù¡¢DCK DCKPʹÓÃÌØÕ÷Properties£º
1)¶î¶¨µçѹΪ450£¯750V¡£¡£¡£¡£¡£
1)Voltage rating 450£¯750V¡£¡£¡£¡£¡£
2)µçÀµ¼ÌåµÄºã¾ÃÔÊÐíÊÂÇéζÈÓ¦²»Áè¼Ý125¡æ¡£¡£¡£¡£¡£
2)AI lowed long term working temperature of the cable conductor shall not exceed 125¡æ£®
3)µçÀ¿ÉÔÚÊÜ¿óÎïÓÍ»òȼÁÏÓÍÎÛȾµÄ³¡ºÏʹÓᣡ£¡£¡£¡£
3)It is suitable for use at mineral-oil or fuel-oil polluted occasions
4)µçÀÂʹÓõÍÇéÐÎζÈÓ¦²»µÍÓÚ55¡æ£®·óÉèζȲ»µÍÓÚ-0¡æ¡£¡£¡£¡£¡£
4)The lowest environmental temperature of cables -55¡æ.The laying temperature should not be les than-0¡æ¡£¡£¡£¡£¡£
5)µçÀ·óÉèµÄÔÊÐíÍäÇú°ë¾¶£º
5)Permissible bending radius of laid cable£®
µçÀÂÍâ¾¶(D)Ϊ20mm¼°ÒÔÏÂÕß¡­¡­¡­¡­¡­¡­¡­¡­Ó¦²»Ð¡ÓÚ3D
The outer diameter (D)of cable up to and including 20mm should not be less than 3D
µçÀÂÍâ¾¶(D)Ϊ20mm¼°ÒÔÉÏÕß¡­¡­¡­¡­¡­¡­¡­¡­Ó¦²»Ð¡ÓÚ5D
The outer diameter(D)of cable beyond 20mm should not be Less than 5D£®
Æß¡¢²úÆ·Ðͺż°ËµÃ÷M0deI Type specification£º
DCK-125 125¡æ×èȼ»ú³µ³µÁ¾ÓÿØÖƵçÀÂ
DCK-125 125¡æ flame-retardant control cable for locomotives
DCKP-125 125¡æ×èȼ»ú³µ³µÁ¾ÓÃÆÁÕÏ¿ØÖƵçÀÂ
DCK-125 125¡æ flame-retardant shielded control cable for locomotives

µÍÑÌÎÞ±×èȼ¹ìµÀ³µÁ¾ÓõçÀÂ:±¾µçÀÂÊÊÓÃÓÚÖÖÖÖ»ú³µ³µÁ¾¼°³Ç¹ìµØÌú³µÁ¾µÄµçÄÜ´«ËÍ¡¢ÐźſØÖÆÒÔ¼°ÆäËüÖÖÖÖÓÐ×èȼҪÇóµÄµçÆ÷×°ÖÃÓᣡ£¡£¡£¡£Ö´Ðбê×¼£ºGB12528.11-2003£¬£¬£¬£¬£¬£¬TB/T1484.1-2001

DCK DCKPÐͺż°Ãû³Æ£º
ÐͺÅ
Ãû³Æ
WDZ-DCYJ-125
½»Áª¾ÛÒÒÏ©¾øÔµÌú·»ú³µ³µÁ¾Óõ¥Ð¾µçÀ£¨µçÏߣ©
WDZ-DCEVM-125
ÌØÖÖµ¯ÐÔÌå¾øÔµÌú·»ú³µ³µÁ¾Óõ¥Ð¾µçÀ£¨µçÏߣ©
WDZ-DCK-125
½»Áª¾ÛÒÒÏ©¾øÔµÌú·»ú³µ³µÁ¾ÓöàоµçÀÂ
WDZ-DCKP-125
½»Áª¾ÛÒÒÏ©¾øÔµÌú·»ú³µ³µÁ¾ÓÃÆÁÕÏÐͶàоµçÀÂ
SLEX
ÌØÖÖ¸´ºÏÖÊÁϾøÔµ¹ìµÀ½»Í¨³µÁ¾ÓöàоµçÀÂ
SPLEX
ÌØÖÖ¸´ºÏÖÊÁϾøÔµ¹ìµÀ½»Í¨³µÁ¾ÓÃÆÁÕÏÐͶàоµçÀÂ


Ïà¹ØÄÚÈÝ

?

Copyright ? 2023-2024 ¹·Íò¹ÙÍø All Rights Reserved.

µØµã£º°²»ÕÊ¡Ì쳤ÊиßÐÂÊÖÒÕ¹¤Òµ¿ª·¢Çø¾­ËÄ·29ºÅ µç»°£º0550-7305800¡¡´«Õ棺0550-7305087

   ±¸°¸ºÅ£ºÍîICP±¸13014508ºÅ-7

ÓÑÇéÁ´½Ó£º ±âµçÀ ÈáÐÔµçÀ ¾íͲµçÀ Åâ³¥µ¼Ïß °²»ÕÌØÖÖµçÀÂ

¹©Ó¦µØÇø£º±±¾©|ÉϺ£|Ìì½ò|ÖØÇì|ºÓ±±|ɽÎ÷|ÄÚÃɹÅ|ÁÉÄþ|¼ªÁÖ|ºÚÁú½­|½­ËÕ|Õã½­|°²»Õ|ºÓÄÏ|¸£½¨|½­Î÷|ɽ¶«|ºþ±±|ºþÄÏ|¹ã¶«|¹ãÎ÷|º£ÄÏ|ËÄ´¨|¹óÖÝ|ÔÆÄÏ|Î÷²Ø|ÉÂÎ÷|¸ÊËà|Çຣ|ÄþÏÄ|н® ÌØÖÖµçÀÂÉú²ú³§¼Ò  
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿